PREVENTING BACKFLOW


Backflow Testing, Prevention & Repair

Call Plumbing Solutions Today for Natural Gas Services!

Plumbing Solutions of Central Florida, Inc.starstarstarstarstar4.8 / 5

209 Total Reviews /files/plumbsol.jpg407-847-0884$2954 Kristin CT, Kissimmee FL



What is Backflow?

Water distribution systems are designed with the intention of the water flowing in a certain direction – from the distribution system to the consumer. However, hydraulic conditions within the system may deviate from the “normal” conditions, causing the water to flow in the opposite direction. Therefore, it is possible and common for the water to flow in the opposite direction in unprotected systems. This is called backflow. When this happens the water system can become contaminated with pollutants that could be harmful to water users.


What Causes Backflow?

Backflow is caused by cross-connections that have the potential of allowing contaminants into the drinking water system. Back siphonage can occur when the pressure in a tank or water trough is lower than the water system’s pressure. This could allow the influx, or pulling, of contaminated water into the system. Another cause of backflow is back pressure. Back pressure occurs when there is higher water pressure in a fire protection system or in a multi-story building that contaminated water could be forced into the public water system.


Testing

Plumbing Solutions is your local backflow assembly testing expert! Call us Today if you need backflow assembly testing.


Repair

Repairing the damage from a backflow issue can be costly! But with Plumbing Solutions by your side, you'll have nothing to worry about! We are your local backflow experts and can help repair the damage, and rectify the situation. Call us today if you need backflow repair!


10% Off for New Customers

Prevention

There are multiple types of backflow preventers, the three most common being the pressure vacuum breaker (PVB), the reduced pressure zone (RPZ), and the double check assembly (DCA). These are all installed in the water system immediately after the isolation valve.

PVB

Pressure vacuum breaker assemblies (PVB) are the most common, inexpensive type of whole-system backflow preventer. It consists of an inlet shutoff valve at the bottom, a single valve body consisting of a pressure vacuum breaker, check valve, and two test cocks, and an outlet shutoff valve. As well as being inexpensive, PVBs are relatively simple in design, and are easy to install, maintain and repair.

DCV

Double check valves (DCV, also called double check assemblies or DCA) are a good choice for underground or indoor installations. A DCA consists of an inlet shutoff valve, two independently operating spring-loaded check valves (usually inside a single valve body), four test cocks, and an outlet shutoff valve.

The DCA is the most common type of approved backflow prevention device for use in underground or in-line installations. In-line (or below-grade) simply means that the backflow device is parallel with the piping of the sprinkler system; unlike the PVB, the DCA does not have to be installed 12 inches above the highest point in the system.

RPZ

Reduced pressure zone assemblies (RPZ), also sometimes called a reduced pressure principle assembly, is the most complex and expensive backflow preventer. However, when working properly, RPZs are the most secure and reliable of all backflow prevention devices. A reduced pressure zone assembly consists of an inlet shutoff valve, two independently operating spring-loaded check valves separated by a pressure differential relief valve, four test cocks, and an outlet shutoff valve.

Send Us A Text Message